Model: NMDP33-G30-50-115
Open Flow: 11.3LPM / 3.0GPM
Amps: 0.46A
Max Amps: 0.78A
110 / 115 / 120 Volt Power Only - 3 prong cord for plug outlet
For FRESH Water use only - not for use with dirty water, salt water, fuels or oils.Open Flow: 11.3LPM / 3.0GPM
Amps: 0.46A
Max Amps: 0.78A
Shut Off Pressure: 50PSI/3.4 Bar
• 3 chamber diaphragm pump
• Intermittent duty
• Industry standard mounting pattern
• Intermittent duty
• Industry standard mounting pattern
• Run dry capable for normal workloads
• Automatic: controlled by pressure switch
• Automatic: controlled by pressure switch
• Ignition protected
• Self priming
• Quiet Operation
• Quiet Operation
APPLICATIONS:
• Yacht, RV, Caravan pressurized water system
• Sprayer fixtures (vehicle-mounted sprayers, electric sprayers)
• Cleaning machines, humidifier, water purification, medical apparatus
• Food beverage filling & liquid transfer
• Solar water system
• Any other pressurization system
• Sprayer fixtures (vehicle-mounted sprayers, electric sprayers)
• Cleaning machines, humidifier, water purification, medical apparatus
• Food beverage filling & liquid transfer
• Solar water system
• Any other pressurization system
Be sure to read booklet before installing. Newmao 115 Volt Instruction Booklet
INSTALLATION:
1.
The pump may be mounted in any position. If mounted vertically, the
pump head should be in the down position to avoid leakage into the motor
casing in the event of a malfunction.
2. Secure the feet, but do not compress them. Over tightening the securing screws may reduce their ability to dissipate noise and vibration.
3. Intake hose must be minimum 1/2" (13 mm) ID reinforced hose. Main distribution line from pump outlet should also be 1/2" (13 mm) ID with branch and individual supply lines to outlets no smaller than 3/8"(10 mm).
4. Plumb the system using high pressure (2x pump rating), braided, flexible tubing to minimize vibration/ noise.
5. Do not apply inlet pressure in excess of 30 psi. In general, try to avoid any inlet pressure completely.
2. Secure the feet, but do not compress them. Over tightening the securing screws may reduce their ability to dissipate noise and vibration.
3. Intake hose must be minimum 1/2" (13 mm) ID reinforced hose. Main distribution line from pump outlet should also be 1/2" (13 mm) ID with branch and individual supply lines to outlets no smaller than 3/8"(10 mm).
4. Plumb the system using high pressure (2x pump rating), braided, flexible tubing to minimize vibration/ noise.
5. Do not apply inlet pressure in excess of 30 psi. In general, try to avoid any inlet pressure completely.
6. Avoid any kinks or fittings which could cause excessive restrictions.
7. Strainer should be attached to the inlet side.
8. The fittings must be secured to avoid leakage.
9. Use clamps at both ends of hose to prevent air leaks into the water line.
10. If a check valve is installed in the plumbing, it must have a cracking pressure of no more than 2 psi.
11. If applying a sealer or plumbing tape, be careful to not over tighten, as they may be sucked into pump.
12. This pump should be wired on its own dedicated circuit. Connect the positive lead (red) to the positive terminal of your battery and the negative wire (black) to the negative terminal of your battery.
13. In an easily accessible location, install a switch to control electricity to the pump. Turn the pump off when not used for extended periods or when the tank is empty.
14. The electrical circuit should be protected with an over-current protection device (fuse) in the positive lead. This pump requires a 18 amp fuse.
15. The pump circuit should not include any other electrical loads.
16. As the water supply pump is non-essential, reference the wire chart under the electrical information. Be sure to have the correct wire sizing for the length of wire you are using.
17. After installation, check the voltage at the pump motor. Voltage should be checked when pump is operating. Full voltage must be available at the pump motor al all times.
7. Strainer should be attached to the inlet side.
8. The fittings must be secured to avoid leakage.
9. Use clamps at both ends of hose to prevent air leaks into the water line.
10. If a check valve is installed in the plumbing, it must have a cracking pressure of no more than 2 psi.
11. If applying a sealer or plumbing tape, be careful to not over tighten, as they may be sucked into pump.
12. This pump should be wired on its own dedicated circuit. Connect the positive lead (red) to the positive terminal of your battery and the negative wire (black) to the negative terminal of your battery.
13. In an easily accessible location, install a switch to control electricity to the pump. Turn the pump off when not used for extended periods or when the tank is empty.
14. The electrical circuit should be protected with an over-current protection device (fuse) in the positive lead. This pump requires a 18 amp fuse.
15. The pump circuit should not include any other electrical loads.
16. As the water supply pump is non-essential, reference the wire chart under the electrical information. Be sure to have the correct wire sizing for the length of wire you are using.
17. After installation, check the voltage at the pump motor. Voltage should be checked when pump is operating. Full voltage must be available at the pump motor al all times.
NOTES:
1.
Flexible potable water hose or PEX tubing is recommended instead of
rigid piping at pump. If you choose to use rigid piping, provide a short
length of hose between pipe and the pump to avoid noise and vibration.
2. We do not recommend the use of metal fillings. When possible, use the provided plastic fittings.
3. Do not adjust the bypass personally without the help of technician.
4. Lack of sanitizing and maintenance is one of the main reasons of under performance of the pump. Please do maintenance and winterize the pump at appropriate times, especially before and after a period of storage.
5. All 115 VAC and 230 VAC pump motors and systems, MUST be ground per local and stale electrical codes.
2. We do not recommend the use of metal fillings. When possible, use the provided plastic fittings.
3. Do not adjust the bypass personally without the help of technician.
4. Lack of sanitizing and maintenance is one of the main reasons of under performance of the pump. Please do maintenance and winterize the pump at appropriate times, especially before and after a period of storage.
5. All 115 VAC and 230 VAC pump motors and systems, MUST be ground per local and stale electrical codes.
115AC ---- BLACK(common),WHITE(neutral),GREEN(ground) ----- #16AWG C-UL-TEW / UL 1015 (or heavier) [Mm')
TROUBLESHOOTING
PULSATING FLOW- PUMP CYCLES ON AND OFF:
• Check lines for kinks.
• Plumbing lines or fittings may be too small.
• Clean faucets and filters.
• Check fitting tightness for air leaks.
• Plumbing lines or fittings may be too small.
• Clean faucets and filters.
• Check fitting tightness for air leaks.
FAILURE TO PRIME BUT MOTOR OPERATES - NO PUMP DISCHARGE:
• Restricted intake or discharge line.
• Air leak in intake line.
• Punctured pump diaphragm.
• Initial amp supply is not enough to sufficiently start the motor.
• Debris clogged in the valves.
• Crack in pump housing.
• Air leak in intake line.
• Punctured pump diaphragm.
• Initial amp supply is not enough to sufficiently start the motor.
• Debris clogged in the valves.
• Crack in pump housing.
MOTOR FAILS TO TURN ON:
• Loose or improper wiring.
• Pump circuit has no power.
• Blown fuse or thermal protection tripped.
• Failed pressure switch.
• Defective motor.
• Pump circuit has no power.
• Blown fuse or thermal protection tripped.
• Failed pressure switch.
• Defective motor.
PUMP FAILS TO TURN OFF AFTER ALL FIXTURES ARE CLOSED:
• Punctured diaphragm.
• Discharge line leak.
• Defective pressure switch.
• Insufficient voltage.
• Clogged valves in pump head
• Discharge line leak.
• Defective pressure switch.
• Insufficient voltage.
• Clogged valves in pump head
LOW FLOW AND PRESSURE:
• Air leak at pump intake.
• Accumulation of debris inside pump or plumbing.
• Worn pump bearing (possibly accompanied by loud noise).
• Punctured diaphragm.
• Defective motor.
• Accumulation of debris inside pump or plumbing.
• Worn pump bearing (possibly accompanied by loud noise).
• Punctured diaphragm.
• Defective motor.
NOISY:
• Check if the mounting feet are compressed too tightly.
• Is the mounting surface flexible? If so, it may be adding noise.
• Check for loose head/screws.
• If the pump is plumbed with rigid pipe, then it may transmit noise more easily.
• Is the mounting surface flexible? If so, it may be adding noise.
• Check for loose head/screws.
• If the pump is plumbed with rigid pipe, then it may transmit noise more easily.
CAUTION:
Please do follow the instruction manual to install the product. Any action outside what is recommended in this manual may bring damage to the pump. Any inappropriate installation or operation that causes the pump damage is not covered by warranty.
Please do follow the instruction manual to install the product. Any action outside what is recommended in this manual may bring damage to the pump. Any inappropriate installation or operation that causes the pump damage is not covered by warranty.